Brief Description
SPFm-F-48-120
16S / 48V / 120A LiFePO4 battery Multi-module BMS
1-1 BMSU: Battery Monitoring & Signaling Unit (BMSU)
1-1-1 With function of cell status monitoring, and SMBus communication port that shows battery status via PC graphic user interface(GUI), BMSU drives Power Mosfet Unit or Relay Switch via dry contact on the board to control current flow.
1-1-2 Execute cell balancing function over a passive battery balance board or an active one.
1-1-3 Show battery capacity via the LED/LCD display Unit or PC GUI.
1-1-4 Control Power Mosfet Switch Unit
1-1-5 Convey warning signals to external receivers that requests battery information.
1-2 Cell Blance Unit(CBU): capable of balancing cell voltage imbalance by 0.5A/1A(Passive
mode)/2A(Active Mode)(Option)
1-3 Power Mosfet Switch Unit : Standalone power mosfet unit with heatsink holds continuous current flow,
Up to 120A and peak at 900A, and load short-circuit at 1200A
1-4 Hall Sensor: Conveying current paramater to BMSU for it to produce information of SoC/ SoH of battery.
1-5 LED Display Unit: capacity on percentage of remaining storage of energy by 4LEDs
And charge/discharge status by 1LED
1-6 USB tool bridge to PC GUI: via this USB tool bridge,user can check up the battery
information from the provided graphic user interface(GUI).
Specifications (custom-made available)
ITEM |
CONDITIONS |
UNIT |
MIN |
TYPICAL |
MAX |
BMS |
For 16S |
V |
|
48 |
|
Ratings |
Voltage Range |
V |
38.4 |
|
57.6 |
Rated Current <=120 |
A |
|
120 |
|
|
Temperature Range |
℃ |
-30 |
|
80 |
|
Charge |
OVP Detection for cell @ |
V |
|
3.65 |
|
OVPR (Release) Detection @ |
V |
|
3.45 |
|
|
Detected OVP Delay Time |
Sec |
|
2 |
|
|
Discharge |
UVP Detection @ |
V |
|
2.40 |
|
UVP Detection Delay time |
Sec |
|
2 |
|
|
UVPR(Release) Detection |
V |
|
2.80 |
|
|
Charge Protection |
OCCP> 120 |
A |
|
120 |
|
OCCP Detection Delay time |
S |
|
2 |
|
|
Discharge Protection |
Max Continuous Discharge Current= 120 |
A |
|
120 |
|
OCCP>122 |
A |
|
122 |
|
|
Detected ODCP Delay time = |
S |
|
15 |
|
|
Over Load short circuit Protection>=650 |
A |
|
650 |
|
|
Over Load Short Circuit Protection Delay time |
mS |
|
31 |
|
|
Short Circuit Protection Detection @ |
A |
|
1200 |
|
|
Short Circuit Protection Detection Delay time |
uS |
|
550 |
|
|
Short Circuit Protection |
|
|
YES |
|
|
|
Hiccup and release after removal of conditions |
|
|
YES |
|
Cell Balance |
Balance Start @ Cell V. variance>30m V or |
V |
|
3.45 |
|
Stop @Cell V. variance<30 mV or @ |
V |
|
3.45 |
|
|
Balance Current ( customization) |
A |
1 |
|
2.5 |
|
Temperature Protection |
OTP in charge when temp out of |
℃ |
0 |
|
55 |
OTPR(release) in charge when inside of |
℃ |
5 |
|
45 |
|
OTP in discharge when temp out of |
℃ |
-20 |
|
70 |
|
OTPR(release) in discharge when inside of |
℃ |
-10 |
25 |
60 |
|
Current consumption |
Operating current consumption |
uA |
|
700 |
|
Current consumption when in quiescence @V=2.2 , 120S |
uA |
|
30 |
|
|
BTS |
NTC 10k+/-1% Ohm b=3435K +/-2% |
|
|
|
|
Forced switch |
Option |
|
|
|
|
Comm. port |
For SMBus |
|
|
|
|
LED |
For SoC // Discharge & charge |
|
|
|
|