Brief Description
SPF-F-36-160
12S / 36V / 160A Smart BMS for 12S*3.2V LiFePO4 battery of golf cart
1. With Graphic User's Interface over SMBus via USB tool kit to PC, to gain battery information, helpful for engineering services., monitoring battery SoC & SoH, such as Amperes, capacity; temperature, protection status and cell balance, event records etc.
2. Conducting back electromotive force (bemf) circuit design..
3. LED display module and tach signal switch, based on Coulomb Counter.(Option)
4. 2-tier system with Mosfet Switch board and monitor-control unit
5. Allowing test vehicle going on slopes of 30° (dgr), multiple surfaces as soft grass and mud
Key Specifications
ITEM |
Condition |
Unit |
Min |
Typical |
Max |
Charge CC/CV |
Standard Charging Voltage :Rated 12S/38.4V |
V |
|
43.2 |
|
Max Charge Current (default) |
A |
|
50 |
|
|
Discharge |
Discharge Voltage :Rated 12S/36V |
V |
28.8 |
|
43.2 |
Max Continuous Discharge Current |
A |
|
160 |
|
|
Over-Charge Protection(OVP) |
OVP Detect Voltage (cell) |
V |
|
3.65 |
|
OVP Release Voltage ( cell) |
V |
|
3.45 |
|
|
OVP Detect Delay Time |
Sec |
|
2 |
|
|
Over Charge Current Protect (OCCP) (default) |
A |
|
160 |
|
|
OCCP Detect Delay Time |
S |
|
2 |
|
|
Under Voltage Protection(UVP) |
UVP Detect Volt ( cell) |
V |
|
2.40 |
|
UVP Detect Delay Time |
Sec |
|
5 |
|
|
UVP Release Voltage( cell) |
V |
|
2.80 |
|
|
UVP Current Consumption |
uA |
|
700 |
|
|
UVP Shut Down Voltage |
V |
|
2.30 |
|
|
UVP Shut Down Current Consumption |
uA |
|
20 |
|
|
Discharge Protection (Adjustable) |
Max Continuous Discharge Current = |
A |
|
160 |
|
Over Discharge Current Protection(ODCP) |
A |
161 |
|
600 |
|
ODCP Detect Delay Time (Adjustable) |
S |
|
40 |
|
|
Second ODCP( software) > |
A |
|
600 |
|
|
Second ODCP Detect Delay Time |
mS |
|
31 |
|
|
Short Circuit Protection(SCP)>= |
A |
|
1200 |
|
|
Short Circuit Protection(SCP.) Delay Time |
uS |
|
550 |
|
|
Hiccup as detected average current remains S.C. |
S |
3 |
|
120 |
|
Release after Removing or by charging for |
S |
|
60 |
|
|
Cell Balance |
Balance Start Volts@ Delta V.>20m V or |
V |
|
3.50 |
|
Balance Release@ Delta V<20m V or |
V |
|
3.50 |
|
|
Balance Capability |
mA |
|
|
170 |
|
Over Temperature Protection(OTP) |
Charge OTP when Temperature out of |
℃ |
0 |
|
60 |
Charge OTP Release as temp. returns in |
℃ |
5 |
|
50 |
|
Dischg OTP when temperature out of |
℃ |
-20 |
|
75 |
|
Dischg OTP Release as temp. returns in |
℃ |
-10 |
|
65 |
|
Current Consumption |
Working Current Consumption in average |
uA |
|
700 |
|
Shut Down Current @ Vcel=2.0 after UVP |
uA |
|
20 |
|
|
Temperature |
Ambient Temp. |
℃ |
- 20 |
25 |
45 |
BTS |
NTC 10k+/-1% Ohm b=3435K +/-2% |
|
|
|
|
Dimension |
218mm*160mm*28mm |
mm |
|
|
|